Product information
MAIPA
Automatically transferred from the PDF. Please compare details with the original document.
Monoclonal Antibody-specific Immobilization of Platelet Antigen assay
The MAIPA Assay is a qualitative in vitro-diagnostic medical device intended for professional laboratory use for the detection and identification of anti-platelet antibodies in serum and plasma samples and for detecting autoantibodies bound to platelets of the patient.
Testprinzip
The test principle is based on the binding of a platelet antigen to a mouse monoclonal antibody that reacts specifically with a human platelet membrane glycoprotein. This is followed by the binding of human antibodies to antigens on this glycoprotein and the analysis of the bound human IgG using an ELISA immunoassay.
Reagents and stability (after opening)
| Reagent | 1 × 96 (900006) | 5 × 96 (900016) | Stability |
|---|---|---|---|
| Screening Cells | 5 x 1 mL | 2 x 12,5 mL | Expiry Date at 2-8°C |
| Identification platelet 1 | 1 x 0,65 mL | 1 x 3,25 mL | Expiry Date at 2-8°C |
| Identification platelet 2 | 1 x 0,65 mL | 1 x 3,25 mL | Expiry Date at 2-8°C |
| Identification platelet 3 | 1 x 0,65 mL | 1 x 3,25 mL | Expiry Date at 2-8°C |
| Identification platelet 4 | 1 x 0,65 mL | 1 x 3,25 mL | Expiry Date at 2-8°C |
| Identification platelet 5 | 1 x 0,65 mL | 1 x 3,25 mL | Expiry Date at 2-8°C |
| Identification platelet 6 | 1 x 0,65 mL | 1 x 3,25 mL | Expiry Date at 2-8°C |
| Control serum/plasma 1a | 1 x 0,4 mL | 1 x 2 mL | Expiry Date at 2-8°C |
| Control serum/plasma 5b | 1 x 0,4 mL | 1 x 2 mL | Expiry Date at 2-8°C |
| Control serum/plasma HLA | 1 x 0,4 mL | 1 x 2 mL | Expiry Date at 2-8°C |
| Control serum/plasma negative | 3 x 0,4 mL | 2 x 3 mL | Expiry Date at 2-8°C |
| Microplate | 1 Plate, 96 Wells | 5 Plates, 5 x 96 Wells | Expiry Date at 2-8°C |
| Anti GPIIbIIIa Antibody | 2 x 0,6 mL | 1 x 12 mL | Expiry Date at 2-8°C |
| Anti IaIIa Antibody | 1 x 1,8 mL | 1 x 9 mL | Expiry Date at 2-8°C |
| Anti IbIX Antibody | 1 x 1,5 mL | 1 x 7,5 mL | Expiry Date at 2-8°C |
| Anti HLA Antibody | 1 x 1,5 mL | 1 x 7,5 mL | Expiry Date at 2-8°C |
| Cell Wash Buffer | 1 x 20 mL | 1 x 100 mL | Expiry Date at 2-8°C |
| Plättchen-Lyse-Puffer | 1 x 15 mL | 1 x 75 mL | Expiry Date at 2-8°C |
| Coated Microplate | 1 Plate, 96 Wells | 5 Plates, 5 x 96 Wells | Expiry Date at 2-8°C |
| Conjugate | 1 x 12 mL | 1 x 60 mL | Expiry Date at 2-8°C |
| ELISA Wash Buffer | 1 x 50 mL | 2 x 125 mL | Expiry Date at 2-8°C |
| TMB-Substrate | 1 x 12 mL | 2 x 30 mL | Expiry Date at 2-8°C |
| Stop Solution | 1 x 12 mL | 1 x 60 mL | Expiry Date at 2-8°C |
Article Nr.: 900006 900016
| Number of determinations | Article number |
|---|---|
| 1 × 96 | 900006 |
| 5 × 96 | 900016 |